| MODEL
90510/90515 |
 |
|
 |
| Description
: |
 |
The Model 90510/90515 is a true
hermetically sealed load cell. Although a canister, it uses
the dual guided cantilever principle for a high degree of
linearity and repeatability. This cell is used in harsh environments
where it may be exposed to water and other contaminants. Typical
applications include batching systems, tank/hopper weighing
and scale conversions
- 100 to 100K pounds capacities
- Hermetically sealed
- Optional Stainless Steel Case
- Optional Dual Bridge
- 2mv or 3mv Outputs avaliable
- Factory Mutual (F.M.) Approved
- Exceeds NIST H-44 requirements
- Replaces RTI 62/63 or 42/43
|
 |
| specifications
: |
 |
| Standard
Capacities : (lbs.) |
100, 200, 300, 500, 750,
1K, 2K, 3K, 5K, 10K, 20K, 50K, 100K |
| Excitation Voltage
: |
10VDC - Maximum 15VDC |
| Rated Output : |
2.0 mv/v ± 0.1% or 3.0 mv/v ± 0.1% |
| Combined Error : |
< 0.05% FSO (Full Scale Output) |
| Zero Balance : |
± 1.0% FSO |
| Bridge Resistance : |
350 ohms ± 3.5 ohms |
| Safe Overload : |
150% of Rated Capacity |
| Safe Side Load
: |
10% |
|
Temperature
:
Compensated
Range :
Effect
of Output :
Effect
on Zero : |
0 - 150 deg. F < 0.0008% FSO/deg. F < 0.0050%
FSO/deg. F (100-300 lbs.)
< 0.0015% FSO/deg. F
(500-10K lbs.) |
| Case : |
Mild Steel |
| Finish : |
Blue Epoxy Paint |
|
 |
| dimensions
: |
 |
|
CAPACITY
(lbs.) |
A |
B |
C Threads |
d |
h
Clearance Rad. |
Weight
(lbs.) |
|
*100-300
|
2.82
|
3.38
|
3/8
- 24UNF - 2B
|
0.40
|
3.00
|
3.0 |
| 500-1K |
3.53 |
4.56 |
1/2 - 20UNF
- 2B |
0.56 |
3.50 |
6.0 |
| 2K-3K |
4.03 |
5.00 |
1/2 - 20UNF
- 2B |
0.56 |
3.80 |
8.0 |
| 5K-10K |
3.50 |
5.94 |
1 - 14UNF -
2B |
1.25 |
3.50 |
10.0 |
| 20K |
5.00 |
8.50 |
1-1/2 - 12UNF - 2B |
2.00 |
4.00 |
15.0 |
| 50K |
6.50 |
11.44 |
1-1/2 - 12UNF - 2B |
2.00 |
4.80 |
40.0 |
| 100K |
6.50 |
11.44 |
2 - 12UNF - 2B |
2.63 |
4.80 |
40.0 |

|
|
|
 |
| applications
: |
 |
- Batching Systems
- Tank / Hopper Weighing
- Scale Conversions
|
| |
|
|
|
|